THC 恆溫恆濕機與分體式冷氣加抽濕機之比較。 THC climate control vs split AC + dehumidifier.
傳統做法為:以分體式冷氣負責溫度控制,另置抽濕機處理濕度,並於冬季增設加濕器補充水份。DBA THC 系列分體式恆溫恆濕氣候控制機則將上述四項功能整合於單一系統 — 然而是否應採用此方案,仍須視乎實際使用需求而定。 The traditional answer: one AC for temperature, one dehumidifier for humidity, a humidifier for dry months. The DBA THC range packs all four jobs into one split-system chassis — but whether it suits your room depends on what you actually need.
何謂 THC 系列?
DBA-THC 系列屬分體式機型,由吊裝於假天花之室內機,搭配室外機(壓縮機與冷凝器組合)所構成。其可同時執行以下四項功能:
- 製冷 — 與一般冷氣機原理相同,負責降低室溫
- PTC 制熱 — 透過陶瓷發熱元件,於低溫天氣提供熱風
- 除濕 — 獨立於溫度控制系統運作,維持目標相對濕度
- 加濕 — 透過內置加濕模組,於乾燥季節(主要為冬季)為室內補充水份
使用者僅須透過單一 LCD 控制面板,設定目標溫度與目標相對濕度,機身即會自動判斷何時執行製冷、制熱、除濕或加濕之指令。本系列共有三款型號:THC35(適用 350 平方呎)、THC50(適用 500 平方呎)、THC66(適用 650 平方呎)。
傳統「冷氣 + 抽濕機」組合方案
香港大部份住宅採用以下三件式組合:
- 分體式冷氣 — 製冷過程中附帶部份除濕效果,惟其顯熱比(SHR)約為 0.75,即每移除 1 kW 之熱量,僅有 0.25 kW 屬潛熱(即水份)
- 移動式或天花式抽濕機 — 用以補足濕度控制功能
- 冬季天氣乾燥時,另行配置獨立加濕器
三件設備各自獨立運作,各設一組控制器,各佔吊頂空間。整體而言佔用空間較多、線路較繁複,風管亦較多,惟個別設備之成本相對較低。
THC 一體式系統之優點
- 單一控制邏輯 — 可避免「冷氣設定 23°C 而抽濕機設定 50% RH」此類設備互相抵觸之情況
- 節省吊頂空間 — 假天花內僅需安裝一部主機及一套風管系統
- 適用於四季 — 香港 12 月至 2 月之室外空氣可降至 30% RH(配合空調運作後室內濕度更低),THC 內置之加濕功能可有效解決皮膚乾裂及家具開裂等問題
- 設計簡潔美觀 — 對於講求室內設計之住宅、會所及精品酒店項目,單一系統有助維持空間之視覺整潔
何種情況下仍應採用傳統組合方案?
- 單位已配置冷氣,僅需額外增設除濕功能 — 加裝 UTC 或 GEC 天花式抽濕機即可,若改用 THC 則須重新鋪設冷媒管線
- 各房間之溫控需求差異較大 — 單一 THC 主機之服務範圍為 350 至 650 平方呎,大型單位可能需配置多部主機,相較之下傳統組合方式更具靈活性
- 預算限制 — THC 機身及安裝費用比 UTC 配普通分體冷氣之組合高出 30 至 50%
- 假天花淨空不足 — THC 機身較深,需要較大之吊頂空間方能容納
能源效益之比較
單純就「冷氣專責製冷」與「THC 兼顧所有功能」進行比較並不公平,因兩者之功能範疇截然不同。較為公允之比較方式為:
- 傳統組合(冷氣加抽濕機加加濕器):總能耗較低,惟三件設備各自於其專屬效率區間內運作
- THC 一體機:總能耗略高,但因單一控制邏輯之故,可避免冷氣與抽濕機之間互相抵觸,實際運轉時間反而較短
根據本公司之實測數據,中型住宅(500 平方呎)採用 THC50 與同等規格之三件式組合相比,年度電費差距約為 ±10%,並非決定性之選型考量因素。最終之關鍵考量在於空間配置與設計需求。
選型建議摘要
新建住宅、精品設計項目、會所,以及需要冬季加濕功能之單位 → 建議採用 THC 系列。
已配置冷氣、預算較為敏感、或吊頂空間受限之單位 → 建議採用冷氣配合 UTC / GEC 抽濕機之組合方案。
What is the THC range?
The DBA-THC range is a split-system: a ceiling-mounted indoor unit paired with an outdoor compressor / condenser. It handles four jobs:
- Cooling — like an air conditioner
- PTC heating — ceramic-element heat for cold spells
- Dehumidification — independent of temperature, holds target RH
- Humidification — built-in module adds moisture in dry months
One LCD panel sets target temperature and target RH; the unit decides when to cool, heat, dehumidify, or humidify. Three sizes: THC35 (350 sq ft), THC50 (500 sq ft), THC66 (650 sq ft).
The traditional "AC + dehumidifier" approach
Most HK homes use:
- Split AC — cools, with incidental dehumidification at SHR ≈ 0.75 (only 25% of the work is latent)
- Mobile or ceiling dehumidifier — handles humidity properly
- Plug-in humidifier for dry winter months
Three boxes, three controllers, three positions. More wiring, more ducting, more space — but lower individual cost.
What the THC integration gains you
- One control logic — no fight between the AC at 23°C and the dehumidifier at 50% RH
- Less plenum real estate — one unit, one duct system
- Year-round coverage — HK winters can hit 30% RH outdoors and lower with AC running; the THC humidifies to keep your skin and furniture from drying out
- Cleaner design — for high-end residential, clubhouses, and boutique hotels, one ceiling system is visually quieter
When the traditional combo still wins
- Existing AC, just adding dehumidification — bolting on a UTC or GEC ceiling unit is cheaper than re-piping for THC
- Multiple rooms with different temperature needs — THC serves 350–650 sq ft per unit; larger homes need several, and a mixed approach can be more flexible
- Budget-constrained — THC capex and install runs 30–50% above a UTC + standard split combo
- Tight ceiling voids — THC chassis is deeper than a UTC; not every plenum fits
Energy comparison
Direct head-to-head is unfair because the systems do different work. A fairer comparison:
- Traditional combo (AC + dehumidifier + humidifier): lower individual energy, but each device sits in its own efficiency band
- THC integrated: slightly higher headline draw, but one control loop avoids the AC-vs-dehumidifier tug-of-war, and total runtime is shorter
In a typical 500 sq ft HK flat, THC50 vs the equivalent three-box combo comes out within ±10% on annual energy. The decisive factor is rarely energy — it is space and design.
The short version
New-build, design-led, clubhouse, or you want winter humidification → THC range. Existing AC, budget-sensitive, tight plenum → keep the AC and add a UTC/GEC ceiling dehumidifier.
項目諮詢Project enquiry
THC 系列是否適合閣下之單位?Is THC right for your space?
本公司可安排現場勘察,並提供系統配置建議與報價。We survey and recommend.
免費諮詢Request a quote